DAP – melt pressure transducer with heated sensor tip

The DAP Series incorporate a heated sensor tip, which limits the potential for sensor damage relating to the membrane, resulting from installation or removal of the pressure transmitter.

The Gneuss patented heated sensor tip allows the sensor to be easily removed from a “frozen” melt without any problems. The diaphragm is not damaged when the polymer contracts. The DAP has revolutionized the handling of critical medias, for example PC, PMMA or ABS.

Information sheet
PDF-Download (1 MB)

Order specification (bar)
PDF-Download (26 KB)

Order specification (psi)
PDF-Download (27 KB)

Operating instructions
PDF-Download (899 KB)

DAP PARASOLID DATA X_T

DAP

DAP 0.5 Zoll-20UNF with flexible capillary

Please download the standard sensor, before collecting the shaft length.

DAP standard sensor (flex)

Shaft length 50 mm

Shaft length 76 mm

Shaft length 152 mm

Shaft length 203 mm

Shaft length 254 mm

Shaft length 318 mm

Shaft length 356 mm

Shaft length 457 mm

  • Heater with 24V
  • Combined pressure- and temperature measurement
  • Highly tough design with flexible components
  • G-coating to counteract adhesive materials
  • Patented technology
  • Removal possible even when extrusion line is down or at ambient temperature
  • Longlife design

DAIP – pressure transmitter with integrated amplifier and heated sensor tip

The DAIP Series incorporates a heated sensor tip, which limits the potential for sensor damage relating to the membrane, resulting from installation or removal of the pressure transmitter. Additionally it offers the comfort of the DAI series in combination with temperature measurement, allowing for heater control.

The Gneuss patented heated sensor tip allows the sensor to be easily removed from a “frozen” melt without any problems. The diaphragm is not damaged when the polymer contracts. The DAIP has revolutionized the handling of critical medias, for example PC, PMMA or ABS.

Information sheet
PDF-Download (462 KB)

Order specification (bar)
PDF-Download (27 KB)

Order specification (psi)
PDF-Download (27 KB)

Operating instructions
PDF-Download (303 KB)

DAIP PARASOLID DATA X_T

DAIP

DAIP 0.5 Zoll-20UNF with flexible capillary

Please download the standard sensor, before collecting the shaft length.

DAIP standard sensor (flex)

Shaft length 50 mm

Shaft length 76 mm

Shaft length 152 mm

Shaft length 203 mm

Shaft length 254 mm

Shaft length 318 mm

Shaft length 356 mm

Shaft length 457 mm

  • Heater with 24V
  • Patented technology
  • Maximum reliabilty through new membrane technology
  • G-coating to counteract adhesive materials
  • Robust design with G-Armor flexible components
  • Interference resistand signals over long distances
  • 3- and 4-wire technology available